Collections:

Skip to product information
1 of 6

ProA1200.1D

Full-rack 2U Class-D network power amplifier with Dante, built-in web-app DSP, 2 x Lo-Z or 1 x Hi-Z outputs, 750 W per channel at 2 or 4 ohm and 1500 W bridged.

  • Dante-compatible 2U Class-D amplifier with 1500 W total system power
  • 2 x Lo-Z channels or 1 x Hi-Z output for 70 V and 100 V lines
  • 1 x 1500 W bridged output at 4 and 8 ohm, 1200 W at 70 V
  • Built-in web-app DSP with multi-zone routing, ducking, EQ, delay and speaker presets
  • Setup over its own Wi-Fi or an RJ45 network port, no extra software
  • Four analog inputs, S/PDIF in and out, GPIO and wall-controller support
  • Automatic standby, PFC universal power supply and full protection circuits
  • 5-year warranty, UL 62368-1 certified
  • SKU:810107710920
  • GTIN:810107710920
  • MPN:ProA1200.1D

You need to login to view the price.

View full details

2U Dante-ready DSP power amplifier, Lo-Z and Hi-Z

Origin Acoustics ProA1200.1D

The Origin PRO ProA1200.1D is a 2U full-rack Class-D power amplifier for commercial installations that need flexible output power and networked audio. It drives either two low-impedance channels or one 70 V or 100 V line, so one amplifier model covers retail, restaurants, fitness studios, auditoriums, houses of worship, hotels and corporate spaces. A complete DSP and zone-management engine is built in and configured through a web app over Wi-Fi or Ethernet, with no extra software or external processor. This Dante-enabled variant adds network audio transport for larger, synchronised projects. Backed by a 5-year warranty from the manufacturer and UL safety certification.

Dante Network Audio Variant

Dante Network Audio Variant

The D suffix marks the Dante-enabled version of the ProA1200.1; the manufacturer states that all other specifications are identical to the non-Dante model. Origin positions Dante for large professional projects where low latency and system-wide synchronisation matter, such as venues, shopping complexes and houses of worship, and where one network cable replaces separate analog runs. For the end user this means a single managed audio network across zones, with amplifier channels patched in software instead of re-cabled. Where no Dante infrastructure exists, the non-D ProA1200.1 offers the same power and DSP.

Lo-Z or 70 V and 100 V in One Model

Lo-Z or 70 V and 100 V in One Model

Each amplifier runs either 2 x Lo-Z channels (750 W each at 2 or 4 ohm, 400 W at 8 ohm) or one bridged output with 1500 W at 4 or 8 ohm, 1200 W at 70 V and 1500 W at 100 V. The mode is chosen in the web app, so the same unit can serve a distributed ceiling-speaker line or a pair of high-power loudspeakers without changing hardware. Per the manual, the two-output model offers one stereo Lo-Z zone, two mono Lo-Z zones or one mono Hi-Z zone; Hi-Z halves the number of outputs because it uses bridged mode. Stocking one SKU for both speaker types simplifies project planning and spares.

2 x 750 W. 1 x 1500 W bridged. Dante-ready.

5-year manufacturer warranty · UL 62368-1 certified · Built-in web-app DSP

Full DSP Without External Processor

Full DSP Without External Processor

The web app is hosted in the amplifier and covers multi-zone setup, input mixing, priority and ducking, parametric EQ on inputs and outputs, high-pass filters, up to 100 ms output delay, compressor, limiters, polarity, FIR import and speaker presets from third-party brands. Presets can be exported, imported and locked against accidental change. In practice, the installer can voice and protect speakers, set paging priority and tune zones from a phone or laptop on site, which reduces rack space, cabling and commissioning time. A built-in sine and pink-noise generator supports system tuning. Password protection is available under Security.

Wi-Fi or RJ45 Commissioning

Wi-Fi or RJ45 Commissioning

Every amplifier broadcasts its own Wi-Fi access point and also has an RJ45 network port, so it can be configured from a phone, tablet or laptop with nothing to install. The wired port gives a stable permanent connection for control systems; the manual lists a fixed default address, DHCP is optional, and it recommends changing the default Wi-Fi password and setting a web-app password when the unit sits on a wired network. This keeps first-time setup fast on site and still allows later remote adjustments through the network, backup and restore of configurations, and firmware updates from the Device menu.

Paging, Priority and Ducking Ready

Paging, Priority and Ducking Ready

Four analog inputs (balanced Euroblock and parallel RCA) plus a stereo S/PDIF input can be freely assigned to zones. Channels 1 and 2 offer a microphone sensitivity setting, though only dynamic microphones are supported because no phantom power is provided. Priority and ducking let a paging or announcement input mute or attenuate background music in selected zones above a set threshold. The S/PDIF output can carry any input or zone to another Origin PRO amplifier, for example one central paging microphone to several amplifiers. This suits restaurants, fitness studios, conference rooms and auditoriums where speech must cut through music reliably.

Control System and Wall Controller Integration

Control System and Wall Controller Integration

A GPIO connector supports remote volume potentiometers, standby and mute switches and a trigger output, and the web app can be set up for in-room controllers from Crestron, Control4 and Q-SYS. Origin also lists a PROZC wall controller (PoE, up to eight per amplifier) and a rotary volume wall controller for these amplifiers, and control driver files are available from the manufacturer. For the end user, volume and source changes happen at the wall instead of through an app, and the amplifier can be integrated into an existing building control system. Note that volume and routing restrictions set in the web app do not apply when a third-party API is used.

Efficient Class-D with Automatic Standby

Efficient Class-D with Automatic Standby

The UMAC Class-D output stage and power-factor-corrected universal supply (100 V to 240 V, 50 or 60 Hz) keep rated power consumption at 350 W for 1500 W total system power, with 203 BTU per hour thermal loss. Outputs mute after five minutes without signal and the amplifier enters standby after fifteen minutes by default, with the temperature-controlled fan switching off in standby; both times are adjustable. The datasheet lists ErP and Energy Star compliance. This lowers energy cost and heat in racks that run in shops, restaurants and hotels every day, while the amplifier wakes on signal, network command or an external switch.

Protected, Certified and Rack-Ready

Protected, Certified and Rack-Ready

Short-circuit, DC, undervoltage, temperature and overload protection guard the amplifier and speakers, and front-panel LEDs show input and output signal, clipping and protection state. The unit is certified to UL 62368-1 and CSA C22.2 No. 62368-1 and is covered by a 5-year manufacturer warranty. It ships with rack ears fitted, is 88 x 440 x 332 mm and weighs 5.9 kg, with adhesive feet for shelf use. The manual requires free airflow at the front and rear, an ambient range of 0 to 40 °C and indoor use. This lets installers rack-mount it quickly and gives the customer long-term support for permanent installations.

Audio28 specifications
Amplifier classClass D
Output circuitryUMAC Class D full-bandwidth PWM modulator
Channels2 x Lo-Z or 1 x Hi-Z
Output power at 2 ohm2 x 750 W (SE)
Output power at 4 ohm2 x 750 W (SE); 1 x 1500 W (BTL)
Output power at 8 ohm2 x 400 W (SE); 1 x 1500 W (BTL)
Output power at 70 V1 x 1200 W (BTL)
Output power at 100 V1 x 1500 W (BTL)
Total system power1500 W
Output voltage (SE unloaded)80 Vp / 160 Vpp
Output voltage (BTL unloaded)160 Vp / 320 Vpp
Signal-to-noise ratio>108 dB (A-weighted, 20 Hz-20 kHz, 8 ohm)
THD+N (typical)<0.05 % (20 Hz-20 kHz, 8 ohm, 3 dB below rated power)
Frequency response20 Hz-20 kHz (+0/-0.5 dB, 8 ohm, 3 dB below rated power)
Power rating reference1 % THD at 120 Vac and 230 Vac
Input sensitivity optionsMic, -10 dBV, +4 dBu, +14 dBu
Maximum analog input level+24 dBu without clipping
Output delayUp to 100 ms per output
Input equalizer5-band per input
Default analog input sensitivity+4 dBu
Input high-pass filterYes (per analog input)
Input gain trimYes (per input)
Output equalizerParametric EQ per output (copyable between outputs)
Zone compressorYes (per zone, default or custom settings)
Output limitersClip, Peak and RMS limiter per output
Hi-Z output high-pass filterYes (default 70 Hz)
S/PDIF output default level-10 dB
Signal detection threshold-60 dB (input signal presence)
Ports & interfaces13 specifications
Network control portRJ45 (Ethernet)
Wireless networkBuilt-in Wi-Fi access point and client mode
Analog audio inputs4 (balanced Euroblock 3.5 mm, plus parallel unbalanced RCA)
Microphone inputsChannels 1 and 2 (dynamic microphones only, no phantom power)
Digital audio input1 x S/PDIF stereo (RCA)
Digital audio output1 x S/PDIF stereo (RCA)
Speaker outputs2 x Lo-Z or 1 x Hi-Z (Euroblock 5 mm)
GPIOYes, configurable (Euroblock 3.5 mm)
Wall control inputYes (mute, standby and more, selectable in web app)
AC mains inputIEC
GPIO functionsRemote volume (potentiometer >10 kΩ), standby, mute and trigger
Front panel power buttonYes
Front panel indicatorsStatus, Input, Output, Network, Wi-Fi
Design4 specifications
Form factor2U full-width rack unit (19 in)
Rack earsFitted (2 pieces)
CoolingTemperature-controlled fan
Protection circuitsShort circuit, DC, undervoltage, temperature and overload
Network9 specifications
DanteYes (Dante-compatible variant)
Configuration interfaceBuilt-in web app (browser, any device)
Default Wi-Fi modeAccess point (client mode selectable)
IP addressingFixed default address or DHCP
Default LAN IP address192.168.64.100
Default Wi-Fi access point IP address192.168.4.1
Web app password protectionYes (Security menu)
Firmware updateVia web app (Settings > Device)
Configuration backup and restoreYes (via web app)
Power8 specifications
Power consumption350 W
Idle power consumption<500 mW
Thermal loss203 BTU/h
Operating voltage and frequency100-240 V AC, 50-60 Hz
Power supplyUREC universal switch-mode supply with PFC and standby converter
Automatic muteAfter 5 minutes without input signal (default)
Automatic standbyAfter 15 minutes without input signal (default)
Standby wake-up triggersInput signal, network 'ON' command, external standby switch or 12 V trigger
Weight & dimensions4 specifications
Width440 mm (17.3 in)
Depth332 mm (13.1 in)
Height88 mm (3.5 in)
Weight5.9 kg
Packaging content1 specification
Included itemsAmplifier, 2 x rack ears (fitted), AC power cable, Euroblock 3.5 mm input connectors, Euroblock 3.5 mm GPIO connector, Euroblock 5 mm output connectors, 4 x adhesive rubber feet, quick start guide
Operational conditions3 specifications
Operating temperature0 - 40 °C
Maximum operating altitude2000 m
Installation environmentIndoor, controlled environment (pollution degree 2)
Certificates5 specifications
Safety standardUL 62368-1 and CSA C22.2 No. 62368-1
Energy complianceErP and Energy Star compliant
Environmental complianceRoHS, REACH, WEEE
Protection classClass I (earthed mains cable required)
UL file numberE536134
Other features17 specifications
Manufacturer warranty5 years (limited)
Multi-zone setupYes (up to zones A-D)
Input mixingYes (mixes equal to number of analog inputs)
Priority and duckingYes
Speaker presetsYes (crossover and gain, EQ, FIR, driver alignment, polarity, limiter, output mode)
Master and slave via S/PDIFYes (daisy-chain link to multiple amplifiers)
Third-party control configurationWall controllers such as Crestron, Control4 and Q-SYS
Signal generatorPink noise and sine
Product seriesOrigin PRO 2U (ProA1200 series)
Autoshare (power sharing)Yes
Zone configurations (2-output models)1 x stereo Lo-Z, 2 x mono Lo-Z or 1 x mono Hi-Z zone
Mono/stereo selectionYes (per input and per zone)
Zone volume limits and routing restrictionsYes (per zone)
Priority/ducking parametersThreshold, attack, hold and release (priority also supports override volume)
S/PDIF output routingAny input or zone, adjustable output level
Speaker preset file formats.zcp (presets), .zcl (preset libraries)
FIR coefficient import formats.csv or .txt

92 specifications verified against the manufacturer's documentation · 31 Oct 2026 · Full datasheet available under Downloads.